Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 78
Filtrar
1.
Rev. bras. ativ. fís. saúde ; 27: 1-14, fev. 2022.
Artigo em Inglês | LILACS | ID: biblio-1382104

RESUMO

Smartphone apps have been developed and investigated in validation studies for tracking human be-havior such as physical activity (PA) and sedentary behavior (SB). However, as it is unclear whether these apps are valid for tracking PA and SB when compared to research-grade accelerometers, thus, this systematic review aimed to investigate the validity of smartphone apps for tracking PA and SB using the accelerometer as a criterion measure. A systematic search was conducted in PubMed, Web of Science, SportDiscus, and Scopus databases. The mean percentage difference (MPD) was used to evaluate criterion validity. Ten studies (n = 662) validating different apps using ActiGraph accelerometers as criteria measure (six were conducted in free-living conditions, two in laboratory conditions, and two in both conditions) were included for analyses. While four apps were considered valid for tracking PA, six were not valid or fully valid. The MPD analysis revealed that apps provide no valid scores for tracking PA measures (MPD = -12.6 ­ 37.7). The scarcity of studies investigat-ing SB limits the tracking of the results on this behavior. Study designs, smartphone location, and exercise intensity tend to affect the accuracy of apps tracking PA; thus, the current review showed conflicting results among studies. This review shows that it is not possible to generalize the valid scores for all apps


Aplicativos para smartphones têm sido desenvolvidos e investigados em estudos de validação para rastrea-mento de comportamento humano, como atividade física (AF) e comportamento sedentário (CS). No entan-to, como não está claro se esses aplicativos são válidos para rastrear AF e CS quando comparados a acelerôme-tros de grau de pesquisa, portanto, essa revisão sistemática teve o objetivo investigar a validade de aplicativos de smartphone para rastreamento de AF e CS usando o acelerômetro como medida de critério. Uma busca sistemática foi realizada em quatro bases de dados. A diferença percentual média (MPD) foi utilizada para avaliar a validade de critério. Dez estudos (n = 662) validando diferentes aplicativos usando acelerômetros ActiGraph como medida de critério (seis foram realizados em condições de vida diária, dois em condições de laboratório e dois em ambas as condições) foram incluídos para análise. Enquanto quatro aplicativos foram considerados válidos para rastreamento de AF, seis não eram válidos ou totalmente válidos. A análise do MPD revelou que os aplicativos não fornecem pontuações válidas para rastrear medidas de AF (MPD = -12,6 ­ 37,7). A escassez de estudos investigando o CS limita o rastreamento dos resultados sobre esse comportamento. Desenhos de estudo, localização do smartphone e intensidade do exercício tendem a afetar a precisão dos aplicativos que rastreiam AF; assim, a presente revisão mostrou resultados conflitantes entre os estudos. Esta revisão mostra que não é possível generalizar as pontuações válidas para todos os aplicativos.


Assuntos
Epidemiologia , Equipamentos de Medição de Riscos , Acelerometria , Postura Sentada
2.
Braz. J. Pharm. Sci. (Online) ; 58: e19558, 2022. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1394032

RESUMO

Abstract Licania macrophylla is a medicinal plant from the Amazon. It is mainly used in the form of a decoction and has been reported to contain several phenolic compounds. However, the effect of seasonality on the phenolic composition and antioxidant potential of this plant has not been well studied, especially in the Amazon region, an area affected by the rainy and less-rainy seasons. Therefore, we evaluated the seasonality of these aromatic compounds and the antioxidant potential of the extracts from L. macrophylla stem bark. We also determined the correlation between the extraction methods used and precipitation levels during each period for 1 year. The total flavonoid and phenolic content, DPPH-scavenging potential, percentage of phosphomolybdenum complex reduction, and iron-reducing power were quantified. The levels of phenolic compounds were the highest in June, whereas those of flavonoids were the highest in September and October; however, these differences were not significant. The extracts from April, November, and June showed the best results for DPPH scavenging, phosphomolybdenum reduction, and iron reduction power, respectively. Significant differences in the phenolic content and DPPH-scavenging activity were observed between the more- and less-rainy seasons. The total phenolic content was positively correlated with FRAP and DPPH, whereas flavonoid levels were negatively correlated.


Assuntos
Plantas Medicinais/efeitos adversos , Estações do Ano , Extratos Vegetais/análise , Chrysobalanaceae/classificação , Compostos Fenólicos , Antioxidantes/análise , Equipamentos de Medição de Riscos
3.
Estud. Psicol. (Campinas, Online) ; 38: e180157, 2021. tab, graf
Artigo em Inglês | INDEXPSI, LILACS | ID: biblio-1133860

RESUMO

Tradeoff analysis, between generalizability, precision, and realism, guides methodological choices in organizational behavior. These methodological choices were systematically reviewed in Brazilian articles and books (1996-2017) to answer the following question: why are there no Brazilian studies on organizational behavior that use big data or analytics? Among 1062 research articles on organizational behavior, published in 19 psychology and business journals, 68% used scales, and only 10% used observation. Observation was often unstructured and supported other methods. The focus was on "saying," instead of "doing". Big data and analytics have the potential to simultaneously reach generalizability, precision, and realism and may pave the way for new conclusions. Additionally, these methods could transform research in organizational behavior.


A análise de custo-benefício entre generalidade, precisão e realismo guia escolhas metodológicas em comportamento organizacional. Estas foram sistematicamente revistas em artigos e livros (1996-2017) brasileiros com o objetivo de responder à pergunta: por que não há estudos em comportamento organizacional no Brasil que usem big data ou analytics? Dentre 1.062 artigos com relatos de pesquisa sobre comportamento organizacional publicados em 19 periódicos de Psicologia e Administração, 68% empregaram escalas e apenas 10% a observação. A observação foi muito frequentemente adotada de forma não estruturada e servindo de suporte a outros métodos. O foco foi no "falar" e não no "fazer". Big data e analytics têm o potencial para atingir ao mesmo tempo a generalidade, a precisão e o realismo e podem abrir o caminho para novas conclusões, sendo talvez capaz de transformar a investigação em comportamento organizacional.


Assuntos
Análise Multivariada , Equipamentos de Medição de Riscos , Técnicas de Observação do Comportamento
4.
Rev. panam. salud pública ; 44: e88, 2020. tab, graf
Artigo em Espanhol | LILACS | ID: biblio-1127118

RESUMO

RESUMEN La hipertensión arterial es una causa modificable muy prevalente de enfermedades cardiovasculares, accidentes cerebrovasculares y muerte. Medir con exactitud la presión arterial es fundamental, dado que un error de medición de 5 mmHg puede ser motivo para clasificar incorrectamente como hipertensas a 84 millones de personas en todo el mundo. En la presente declaración de posición se resumen los procedimientos para optimizar el desempeño del observador al medir la presión arterial en el consultorio, con atención especial a los entornos de ingresos bajos o medianos, donde esta medición se ve complicada por limitaciones de recursos y tiempo, sobrecarga de trabajo y falta de suministro eléctrico. Es posible reducir al mínimo muchos errores de medición con una preparación adecuada de los pacientes y el uso de técnicas estandarizadas. Para simplificar la medición y prevenir errores del observador, deben usarse tensiómetros semiautomáticos o automáticos de manguito validados, en lugar del método por auscultación. Pueden ayudar también la distribución de tareas, la creación de un área específica de medición y el uso de aparatos semiautomáticos o de carga solar. Es fundamental garantizar la capacitación inicial y periódica de los integrantes del equipo de salud. Debe considerarse la implementación de programas de certificación de bajo costo y fácilmente accesibles con el objetivo de mejorar la medición de la presión arterial.(AU)


ABSTRACT High blood pressure (BP) is a highly prevalent modifiable cause of cardiovascular disease, stroke, and death. Accurate BP measurement is critical, given that a 5-mmHg measurement error may lead to incorrect hypertension status classification in 84 million individuals worldwide. This position statement summarizes procedures for optimizing observer performance in clinic BP measurement, with special attention given to low-tomiddle- income settings, where resource limitations, heavy workloads, time constraints, and lack of electrical power make measurement more challenging. Many measurement errors can be minimized by appropriate patient preparation and standardized techniques. Validated semi-automated/automated upper arm cuff devices should be used instead of auscultation to simplify measurement and prevent observer error. Task sharing, creating a dedicated measurement workstation, and using semi-automated or solar-charged devices may help. Ensuring observer training, and periodic re-training, is critical. Low-cost, easily accessible certification programs should be considered to facilitate best BP measurement practice.(AU)


RESUMO A hipertensão é uma causa altamente prevalente de doença cardiovascular, acidente vascular cerebral e morte. A medição precisa da pressão arterial (PA) é um aspecto crítico, uma vez que erros de mensuração da ordem de 5 mmHg podem levar a uma classificação incorreta do status de hipertensão em 84 milhões de pessoas em todo o mundo. O presente posicionamento resume os procedimentos para otimizar o desempenho do observador (o indivíduo responsável pela mensuração da PA) na mensuração clínica da PA, com atenção especial para contextos de baixa a média renda, onde recursos limitados, cargas de trabalho pesadas, restrições de tempo e falta de energia elétrica tornam mais desafiadora a tarefa de medir a PA. Muitos erros de mensuração podem ser minimizados pela preparação adequada do paciente e pelo uso de técnicas padronizadas. Para simplificar a mensuração e evitar erros do observador, devem-se utilizar dispositivos semiautomatizados ou automatizados validados, com manguito para braço, ao invés de auscultação. O compartilhamento de tarefas, a criação de uma estação de trabalho dedicada à mensuração e o uso de dispositivos semiautomatizados ou com carga solar podem ajudar. É essencial que seja assegurado o treinamento e retreinamento periódico do observador. Programas de certificação de baixo custo e de fácil acesso devem ser considerados para facilitar a adoção das melhores práticas na mensuração da PA.(AU)


Assuntos
Humanos , Oscilometria , Monitores de Pressão Arterial/provisão & distribuição , Saúde Global/tendências , Equipamentos de Medição de Riscos , Hipertensão/prevenção & controle
5.
Fisioter. Mov. (Online) ; 33: e003314, 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1090396

RESUMO

Abstract Introduction: Spine problems are common, and assessment of spine flexibility provides relevant information; however, alternative evaluation methods need to be validated. Objective: To evaluate the concurrent validity of the Flexicurve using 3D videogrammetry as a reference value to assess spinal flexion and extension in the lumbar and thoracic regions. Method: The consecutive sample consisted of 39 individuals aged between 18 and 50 years. Two consecutive evaluations were performed by the same rater on the same day and at the same location: (1) Flexicurve and (2) 3D videogrammetry. The assessments were performed with the spine in the neutral position, followed by maximum flexion and extension. The range of motion (ROM) in the maximum flexion and extension positions was calculated in MATLAB® and defined as the difference between the maximum flexion or extension angle and that of the neutral position. Statistical analyses used were the Pearson Product-Moment Correlation coefficient, RMS error and Bland-Altman plot (α < 0.05). Results: The ROM between instruments was similar, with high correlations for thoracic flexion (r = 0.751), extension (r = 0.814) and lumbar flexion (r = 0.853), and RMS errors under 8°. The correlation for lumbar extension was moderate (r = 0.613) and the RMS error was more than 10°. The limits of agreement varied between ± 10º and ± 21º. Conclusion: The Flexicurve is valid for assessing maximum flexion and extension of the thoracic spine, and maximum flexion of the lumbar spine. We suggest caution in evaluating the maximum extension of the lumbar spine.


Resumo Introdução: Problemas na coluna vertebral são frequentes, sendo a avaliação da flexibilidade uma informação relevante a ser considerada pelo profissional. Métodos alternativos para realizar avaliação da flexibilidade da coluna carecem de validação. Objetivo: Avaliar a validade concorrente do Flexicurva utilizando a videogrametria 3D como medida de referência, para a avaliação da flexibilidade em flexão e extensão da coluna vertebral torácica e lombar. Método: A amostra consecutiva contou com 39 indivíduos com idades entre 18 e 50 anos. Duas avaliações consecutivas foram realizadas pelo mesmo avaliador no mesmo dia e local: (1) Flexicurva e (2) videogrametria 3D. As avaliações foram realizadas com a coluna na posição neutra, seguida das posições de flexão e extensão máximas. A ADM nas posições de flexão e extensão máximas foram calculadas no MATLAB®, sendo definida como a diferença entre os ângulos máximos de flexão ou extensão e a angulação da posição neutra. Na análise estatística utilizou-se: Teste de Correlação Produto-Momento de Pearson, Erro RMS e Análise de Bland-Altman. (α < 0,05). Resultados: Os valores de ADM entre os instrumentos foram similares, com correlações altas para a flexão torácica (r = 0,751), extensão torácica (r = 0,814) e para flexão lombar (r = 0,853), com erros RMS inferiores a 8°. Para a extensão lombar a correlação foi moderada (r = 0,613), com erro RMS superior a 10°. Limites de concordância variaram entre ± 10º e ± 21º. Conclusão: O Flexicurva mostrou-se válido para avaliar o movimento flexão máxima e extensão máxima da coluna torácica, e flexão máxima da coluna lombar. Sugerimos cautela na avaliação da extensão máxima da coluna lombar.


Resumen Introducción: Los problemas en la columna vertebral son frecuentes, siendo la evaluación de la flexibilidad de la columna vertebral una información relevante a ser considerada por el profesional. Los métodos alternativos para realizar la evaluación de la flexibilidad de la columna necesitan validación. Objetivo: Evaluar la validez concurrente del Flexicurva utilizando la videogrametría 3D como medida de referencia para evaluar la flexión y extensión de la columna en las regiones lumbar y torácica. Método: La muestra consecutiva consistió en 39 individuos de edades comprendidas entre 18 y 50 años. El mismo evaluador realizó dos evaluaciones consecutivas en el mismo día y local: (1) Flexicurve (2) Videogrametría 3D. Las evaluaciones se realizaron con la columna en posición neutral seguida de la máxima flexión y extensión. El RDM en la posición máxima de flexión y extensión se calculó en MATLAB®, la flexión máxima y la extensión se definieron como la diferencia entre el ángulo de la posición con respecto al punto neutro. Los análisis estadísticos consistieron en la prueba de correlación de producto-momento de Pearson, error de RMS y los análisis de Bland-Altman (α < 0,05). Resultados: Los valores de RDM entre instrumentos fueron similares, con altas correlaciones para flexión torácica (r = 0.751), extensión torácica (r = 0.814) y flexión lumbar (r = 0.853), y errores RMS por debajo de 8°. Para la extensión lumbar, se moderó la correlación (r = 0,613) y el error RMS fue superior a 10°. Los límites de concordancia variaron entre ± 10º y ± 21º. Conclusión: El Flexicurva se mostró válido para evaluar la flexión máxima y la extensión máxima de la columna torácica, y la flexión máxima de la columna lumbar. Sugerimos precaución al evaluar la extensión máxima de la columna lumbar.


Assuntos
Humanos , Adulto , Coluna Vertebral , Maleabilidade , Equipamentos de Medição de Riscos , Estudo de Validação
6.
Artigo em Espanhol | LILACS, SaludCR | ID: biblio-1389052

RESUMO

Resumen Objetivo: Diseñar y validar un instrumento para vigilar los factores de riesgo de enfermedad cardiovascular en la población del cantón central de Cartago. Introducción: La vigilancia epidemiológica es un proceso regular y continuo de observar e investigar la morbi mortalidad y sus factores de riesgo para su análisis, interpretación y uso. La enfermedad cardiovascular es la principal causa de muerte en la mayoría de los países del mundo siendo necesario vigilar sus factores de riesgo. Métodos: Basado en una estrategia de medición y análisis integral de la mayoría de los factores de riesgo cardiovascular, se diseñó y validó un método para su vigilancia. Resultados: El método se ha aplicado en 6 empresas, 13 escuelas y colegios, 13 comunidades y 13 instituciones y asociaciones para un total de 2940 personas, con los resultados siguientes; sedentarismo 69.30%, obesidad 59.4%, enfermedad cardiovascular familiar 52.4%, padecer diabetes, hipertensión y/o colesterol alto 46.2%, estrés 39.65%, presión arterial alta 29.5%, colesterol total alto 31.0%, tabaquismo 17%, glicemia alta 2.7% y evento cardiovascular anterior 0.2%. Discusión: La vigilancia epidemiológica es básica para promover la salud y prevenir la enfermedad cardiovascular. El reto es contar con una metodología de bajo costo, buena confiabilidad y alta aceptación por los usuarios y colaboradores en la vigilancia. El método ha permitido medir y valorar los factores de riesgo cardiovascular satisfaciendo en buena manera los criterios indicados anteriormente.


Abstract Aim: Design and validate an instrument to survey el cardiovascular disease´s risk factors in the population of the city of Cartago. Introduction: Epidemiological surveillance is a steady and continuous process of observation and researching of the morbidity and mortality and its risk factors for analyzing, interpreting and using the information. Cardiovascular disease is the main cause of death in most countries in the world, being required to survey its risk factors. Methods: Based on a strategy of mesurement and comprehensive analysis of most cardiovascular risk factors, it was designed and validated a method for its surveillance. Results: The method has been employed in 6 companies, 13 primary and secundary schools, 13 communities and 13 institutions and associations, suming a total of 2949 people. It was obtained the following: 69.3% sedentary lifestyle, 59.4% obesity, 52.4% relatives cardiovascular disease, 46.2% diagnosed diabetes, hypertension and/or elevated colesterol, 39.65% stress, 29.5% hypertension at the moment of the survey, 31.0% high total colesterol at the moment of the survey, 17% smoking, 2.7% high blood glucose level and 0.2% a previous cardiovascular event. Discussion: Epidemiological surveillance is basic for promoting health and avoiding cardiovascular disease. The challenge is to count on a low cost, good reliability and high users and colaborators acceptance methodology. The method has allowed to mesure and assess the cardiovascular risk factors, satisfying properly the guidelines mentioned above.


Assuntos
Humanos , Exercício Físico/fisiologia , Equipamentos de Medição de Riscos , Fatores de Risco de Doenças Cardíacas , Costa Rica
7.
Braz. arch. biol. technol ; 62: e19180372, 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1001421

RESUMO

Abstract The objective of this study was to construct and validate an instrument that evaluates the Quality of Work Life (QWL) globally, following the WHOQOL instruments and founded in QWL's classical theoretical models, directed to the contemporary society. The psychometric properties tested were content validity, face validity, internal consistency, criterion validity, concurrent validity and test-retest reliability in an application to 283 individuals. The final version of the instrument is constituted by 47 questions, being five to sample knowledge and 42 divided in five spheres that contemplate QWL's dimensions. For the results calculation a SPSS syntax and a tool in Microsoft Excel that perform the automated calculation after the data tabulation were developed. The psychometric properties tested were satisfactory. We conclude that the goal of validating a global instrument for evaluation of QWL from the contemporary society culture with satisfactory psychometrical characteristics was reached.


Assuntos
Qualidade de Vida , Psicometria/métodos , Equipamentos de Medição de Riscos
8.
Braz. arch. biol. technol ; 61(spe): e18000032, 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-974157

RESUMO

ABSTRACT The present work presents the development of a system of measurement of electric energy consumption. This system shows the consumer the amount of energy consumed and its respective monetary value in real time. The prototype was used in a case study to validate its operation. Data were collected to discuss the results obtained. In order to verify if the results obtained in the prototype were correct, several measurements of energy consumption were made in different residential equipment. The consumption values measured by the prototype were compared with the values obtained by the certified and calibrated energy meter provided by COPEL and were satisfactory.


Assuntos
Equipamentos de Medição de Riscos , Eletricidade , Abastecimento de Energia/métodos , Consumo de Energia
9.
Arq. bras. med. vet. zootec. (Online) ; 69(6): 1551-1559, nov.-dez. 2017. ilus, graf
Artigo em Português | LILACS, VETINDEX | ID: biblio-910563

RESUMO

O objetivo deste estudo foi utilizar a sonda uretral flexível como método alternativo para aferição da pressão intracraniana em coelhos com trauma cranioencefálico induzido pelo cateter de Fogarty 4 Fr (balão epidural) e comparar os dados obtidos com o método convencional de cateter de ventriculostomia. Foram utilizados 12 coelhos, machos, adultos, distribuídos aleatoriamente em dois grupos, denominados de G1: mensuração da PIC com cateter de ventriculostomia (n=6) e G2: mensuração com sonda uretral (n=6). Foram realizadas duas craniotomias na região parietal direita e esquerda para a implantação do cateter de ventriculostomia ou sonda uretral flexível e o balão epidural, respectivamente. A PAM, a PPC, a FC, a FR e a TR foram mensurados antes e após a craniotomia. A PIC foi avaliada após a craniotomia e a cada 10 minutos depois do preenchimento do balonete com 0,3mL de NaCl 0,9%, durante 40 minutos, e com 0,6mL, pelo mesmo período de tempo, totalizando 80 minutos. A PIC aumentou em ambos os grupos, sendo menores os valores registrados com a sonda uretral flexível. Foi possível reproduzir o aumento da PIC com o modelo experimental de TCE utilizando o cateter de Fogarty 4 Fr na região epidural e, embora haja a necessidade de outros estudos, a sonda uretral flexível demonstra ser um método alternativo de mensuração da PIC em coelhos com trauma cranioencefálico.(AU)


The aim of this study was to evaluate the use of flexible urethral catheter as an alternative method for measuring intracranial pressure in rabbits with head trauma induced by 4 F Fogarty catheter (epidural balloon) and compare the data obtained with the conventional method of ventriculostomy catheter. In this study, New Zealand rabbits were randomly distributed into two groups, G1: measuring the ICP with ventriculostomy catheter (n=6) and G2: measuring the ICP with urethral catheter (n=6). Two craniotomies were performed in the right and left parietal region for the implantation of a ventriculostomy catheter and/or flexible urethral catheter and epidural 4 Fr Fogarty arterial embolectomy catheter, respectively. MAP, CPP, HR, RF and RT values were measured before and after of the craniotomy. The ICP value was measured after craniotomy, every five minutes during 40 minutes after the balloon was inflated with 0.3 ml with NaCl and further 40 minutes after the balloon was inflated with 0.6 ml. The ICP value increased in both groups; however, the ICP values were lower in the flexible urethral catheter. The flexible urethral catheter can be used as an alternative method to measure ICP values in rabbits with head injury.(AU)


Assuntos
Animais , Coelhos , Pressão Intracraniana , Equipamentos de Medição de Riscos , Cateterismo Urinário/estatística & dados numéricos , Cateterismo Urinário/veterinária , Traumatismos Craniocerebrais/diagnóstico , Ventriculostomia/veterinária
10.
ImplantNewsPerio ; 2(5): 868-873, set.-out. 2017. ilus, tab
Artigo em Português | LILACS, BBO - odontologia (Brasil) | ID: biblio-877282

RESUMO

Objetivo: avaliar, por meio de extensometria, a transmissão da carga mastigatória axial ao osso de suporte em próteses unitárias implantossuportadas por implantes de diferentes comprimentos. Material e métodos: em um bloco de poliuretano que simula 2 mm de osso cortical e o restante de medular, segundo a norma ASTM­F1839, com 22 mm x 16 mm x 150 mm, foram instalados quatro implantes cone-morse infraósseos 2 mm: G1) 4 mm x 7 mm; G2) 4 mm x 9 mm; G3) 4 mm x 11 mm; G4) 4 mm x 13 mm. Sobre os mesmos, foram instalados pilares do tipo esteticone e cilindros metálicos. Dois extensômetros lineares foram colados na superfície do bloco, tangenciando a plataforma de cada implante (mesial e distal). Em uma máquina de ensaio universal, foi aplicada uma carga de 100 N sobre a superfície oclusal de cada cilindro. Para cada grupo, foram realizados cinco medições e os dados obtidos em microdeformacão (µÆ). Foi verificada a normalidade dos dados pelo teste de Shapiro-Wilk e realizada a análise de variância 1 critério (p < 0,05), e o teste Tukey (p  0,5). Resultados: as médias e os desvios-padrão das amostras foram, respectivamente, G1: 346.16,3 ± 10,28 µÆ; G2: 216.91 ± 15,47 µÆ; G3: 114,41 ± 2,33 µÆ; e G4: 76.83,3 ± 7,13 µÆ. O teste de Shapiro-Wilk constatou a normalidade dos dados, e os testes Anova e Turkey a diferença estatística significante entre todos os grupos. Conclusão: para cargas axiais, implantes com menor comprimento produziram maior deformação no osso superfi cial.


Purpose: the aim of this study was to evaluate, by extensometry, the transmission of the axial masticatory load to supporting bone around implants of different lengths. Material and methods: in a block of polyurethane that simulates 2 mm of cortical bone and the remaing of medullary bone, according to the ASTM-F1839 standard, with 22 mm x 16 mm x 150 mm, were installed 4 morse tappered dental implants, 2 mm subcrestal: G1) 4 mm x 7 mm; G2) 4 mm x 9 mm; G3) 4 mm x 11 mm; G4) 4 mm x 13 mm. Estheticone-like abutments and metallic cylinders were placed. Two linear strain gauges were bonded on block surface, tangential to the platform of each implant (mesial and distal). A 100 N load on the occlusal surface of each cylinder was applied to a universal test machine. For each group, five measurements and the data obtained in microdeformation (µÆ) were performed. The normality of the data was verified by the Shapiro-Wilk test and (p < 0.05) and Tukey's test (p  0.5). Results: the means and standard deviation of the samples were respectively G1: 346.16.3 ± 10.28 µÆ; G2: 216.91 ± 15.47 µÆ; G3: 114.41 ± 2.33 µÆ; G4: 76.83.3 ± 7.13 µÆ. The Shapiro-Wilk test exhibit the normality of the data, and the Anova and Turkey tests exhibit statistically significant difference between all groups. Conclusion: axial load produced more tension for short implants on the superficial bone.


Assuntos
Humanos , Análise de Variância , Fenômenos Biomecânicos , Força de Mordida , Implantação Dentária , Análise de Elementos Finitos , Equipamentos de Medição de Riscos , Técnicas In Vitro
11.
Mem. Inst. Invest. Cienc. Salud (Impr.) ; 15(2): 108-117, ago. 2017. ilus, graf
Artigo em Espanhol | LILACS, BDNPAR | ID: biblio-869112

RESUMO

Un creciente reconocimiento de la importancia de la calidad de vida en odontología ha llevado al desarrollo de varios instrumentos para medir su relación con la salud bucodental. Saber por qué y de qué manera la salud bucodental afecta la calidad de vida de las personas es relevante para la práctica, la investigación y la enseñanza en odontología. El objetivo de esta revisión bibliográfica fue actualizar los conocimientos sobre las características generales y sicométricas de los instrumentos para medir la calidad de vida relacionada a la salud bucodental que surgieron posterior a la publicación en 1997 de los resultados de la conferencia "Measuring oral health and quality of life”. Se realizó una búsqueda bibliográfica para identificar publicaciones aparecidas de enero de 1998 a junio del 2011, utilizando las bases de datos MEDLINE y GOOGLE académico. Se establecieron criterios específicos, basados en marcos de referencia internacionales, para la inclusión, la recolección y el análisis de las propiedades generales y sicométricas de los instrumentos. Se identificaron 233 artículos de los cuales 10 cumplían con todos los criterios predeterminados y finalmente quedaron 9 porque uno de ellos se encontraba repetido. Todas las publicaciones fueron encontradas en lengua inglesa. Todos los instrumentos fueron multidimensionales, presentaron propiedades sicométricas adecuadas y la mayoría de ellos tomó como base a otros instrumentos de medición previos y a la clasificación de deficiencias y discapacidades. Se concluye que es necesario avanzar en la medición de salud bucodental relacionada a la calidad de vida para el contexto y las características de la población de América Latina ya que sólo se cuenta con publicaciones anglosajonas.


There is growing recognition of the importance of oral health-related quality of life.This has given rise to the development of various instruments to measure therelationship between quality of life and oral health. Understanding why and how oralhealth affects quality of life is highly relevant to the research, teaching and practice ofprofessional dentistry. The objective of this literature review was to update theknowledge about the general and psychometric characteristics of instruments tomeasure quality of life related to oral health that emerged after the publication in 1997of the results of the conference "Measuring oral health and quality of life”. We conducted a literature review using MEDLINE and GOOGLE Scholar databases to identifypublications that appeared between January, 1998 and June, 2011. We used commoninternational frames of reference to establish specific search criteria for the inclusion,collection, and analysis of the general and psychometric properties of the instruments.We identified 233 articles, ten of which met all the established criteria. Ultimately wereduced this number to nine because one of the articles was a duplicate. All identifiedarticles were in English. All instruments identified through the literature review weremultidimensional and had adequate psychometrtic properties. The majority ofinstruments was based on prior measurement tools and the classification of impairmentsand disabilities. We conclude that to advance the measurement of oral health-relatedquality of life, the specific context and characteristics of the Latin American populationshould be taken into account. So far, this topic has only been addressed in Englishlanguage publications.


Assuntos
Humanos , Qualidade de Vida , Dispositivos para o Cuidado Bucal Domiciliar , Equipamentos de Medição de Riscos , Saúde Pública
13.
Int. j. cardiovasc. sci. (Impr.) ; 30(2): f:100-l:108, mar.-abr. 2017. tab
Artigo em Português | LILACS | ID: biblio-833892

RESUMO

Fundamento: A hipertensão arterial é o principal fator de risco cardiovascular. A qualidade técnica dos esfigmomanômetros é condição fundamental para obtenção da correta medida da pressão arterial. Objetivos: Avaliar o perfil dos esfigmomanômetros disponíveis nos serviços de urgências de Belo Horizonte, Minas Gerais. Métodos: Realizamos um estudo transversal, observacional e não intervencionista para avaliar o perfil dos esfigmomanômetros disponíveis nos prontos atendimentos de adultos de hospitais públicos e privados do município de Belo Horizonte. Avaliamos 337 aparelhos de 25 hospitais, sendo 15 públicos (do total de 16) e 10 privados (do total de 12). Resultados: Foram observadas inadequações dos equipamentos em relação à validação pelo Instituto Nacional de Metrologia, Qualidade e Tecnologia ­ INMETRO, em 26% (88/337) dos equipamentos; calibração vencida em 39% (132/337) e não correspondência de marca aparelho/braçadeira em 54% (188/337). Em 13 dos 25 hospitais (52%), não havia disponibilidade de manguitos para braços de diferentes tamanhos além do padrão. Houve superioridade de adequação dos aparelhos aneroides e de mercúrio dos hospitais privados (p = 0,038 e p < 0,001, respectivamente) e dos eletrônicos nos públicos (p < 0,001). Conclusão: Conclui-se que 78% dos esfigmomanômetros disponíveis nos serviços de urgência/emergência de uma das maiores capitais brasileiras apresentavam inadequações técnicas, e em metade dos serviços não havia manguitos de diferentes tamanhos. Tal fato representa um alerta para a situação dos equipamentos disponíveis para atendimento da população no país


Background: Hypertension is the main risk factor for cardiovascular diseases. Technical quality of sphygmomanometers is a prerequisite for the correct measurement of arterial pressure. Objectives: To evaluate sphygmomanometers available in emergency services in the city of Belo Horizonte, Brazil. Methods: We performed a cross-sectional, observational, non-interventional study to evaluate characteristics of the sphygmomanometers available in adult emergency services of public and private hospitals in the city of Belo Horizonte, Brazil. We evaluated 337 sphygmomanometers of 25 hospitals ­ 15 (of 16) public hospitals and 10 (of 12) private hospitals. Results: Twenty-six percent (88/337) of devices were considered inadequate regarding the INMETRO (National Institute of Metrology, Quality and Technology) standards, 39.2% (132/337) for calibration dates, and 54% (188/337) for the mismatching between cuff's and device's brands. In 13 of 25 hospitals (52%), there were no spare cuffs in different sizes for different arm circumferences. Higher adequacy was found for aneroid and mercury sphygmomanometers used in private hospitals (p = 0.038 and p < 0.001, respectively) and electronic devices used in public hospitals (p < 0.001) compared with others.Conclusion: Seventy-eight percent of sphygmomanometers available in emergency services had technical inadequacies, and half of these services had no spare cuffs in different sizes available. These findings serve as a warning of the conditions of the equipment used in healthcare services provided to the general population in Brazil


Assuntos
Hospitais Privados/normas , Hospitais Públicos/normas , Hipertensão/complicações , Esfigmomanômetros , Saúde do Adulto , Doenças Cardiovasculares/fisiopatologia , Vasos Coronários/fisiologia , Manutenção de Equipamento/análise , Manutenção de Equipamento/métodos , Equipamentos de Medição de Riscos , Estudo Observacional , Atenção Primária à Saúde/métodos , Fatores de Risco , Interpretação Estatística de Dados , Inquéritos e Questionários
14.
Rev. cuba. oftalmol ; 30(1): 0-0, ene.-mar. 2017. graf
Artigo em Espanhol | LILACS | ID: biblio-901347

RESUMO

La salud es un elemento decisivo de la calidad de vida. El concepto de calidad de vida es cada vez más utilizado como medida del bienestar y depende de elementos objetivos y de la valoración subjetiva que el paciente hace de diferentes aspectos de su vida. Las pruebas de calidad de vida son adaptables al campo de la Oftalmología y aplicables a cualquier paciente, además de las pruebas de función visual. El NEI VFQ-25 mide las dimensiones del estado de salud orientado a la visión. El uso de estos estudios permite conocer la respuesta clínica y el grado de satisfacción del paciente, lo que conlleva una mejor calidad de vida. Con la presente investigación se pretende mostrar una de las pruebas más utilizadas para describir los resultados de la calidad visual(AU)


The health is a decisive element of the life quality. The quality of life concept is more and more utilized, it depends on objective elements, and subjective opinion of the patient makes of different aspects of its life. The quality of life test is adaptive to the ophthalmology patient, beside the tests of visual function. The NEI VFQ-25, measures the dimensions from the health to the vision. The use of these studies allows knowing the clinical response and the patient satisfaction, what means a better life quality(AU)


Assuntos
Humanos , Equipamentos de Medição de Riscos , Satisfação do Paciente , Qualidade de Vida , Testes de Campo Visual/estatística & dados numéricos
15.
Braz. j. biol ; 77(1): 01-11, Jan-Mar. 2017. map, ilus, tab, graf
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1468374

RESUMO

Intra-specific color variation is often underestimated by researchers, and among mammals, intra-specific differences in coloration are poorly documented for most species. The main goal of this study was to apply an objective color measurement methodology to the study of a specific problem: the detection, if any, of patterns of changes in the fur color of specimens of Akodon budini in relation to biological (i.e., sex) and environmental (i.e., season) variables. We hypothesize that coat color will be more homogeneous in males than in females and that coat color will be darker in winter than in summer, the latter being orange. We measured the pelage color on five points over the dorsal surface of 26 A. budini museum specimens using a spectroradiometer and a diffuse illumination cabin. We used Principal Component Analysis to describe the association between the color variables, sex and season, and each of the observations. We then used general linear models of Analysis of Variance to examine relationships between color data, season, and sex. The results clearly confirm the hypothesis related to seasonal coat color change but do not directly confirm the hypothesis related to changes in coat color in relation to sex, and we show the complexity of the studied pattern. In conclusion, undoubtedly, the studied variables should accordingly be considered when studying the coloration of specimens for characterization, identification and discrimination of different taxonomic units based on color.


Variação de cor intra-específica é muitas vezes subestimada pelos pesquisadores, e entre espécies de mamíferos, as diferenças intra-específicas na coloração são pouco conhecidas para a maioria das espécies. O principal objetivo deste estudo foi aplicar uma metodologia objetiva de medição de cor para o estudo de um problema específico: a detecção de padrões de mudanças na cor da pele de espécimes de Akodon budini em relação a variáveis biológicas (i.e., sexo) e ambientais (i.e., temporada), se houver. Nossa hipótese é que a cor da pelagem do sexo masculino será mais homogênea do que a de fêmeas e que a cor da pelagem do inverno vai ser mais escura do que a de verão, sendo esta última mais laranja. Medimos a cor da pelagem em cinco pontos sobre a superfície dorsal de 26 espécimes de museu de A. budini usando um espectroradiômetro e uma cabine de iluminação difusa. Usamos Análise de Componentes Principais para descrever a associação entre as variáveis de cor, sexo e temporada, e cada uma das observações. Em seguida, usamos modelos lineares gerais da Análise de Variância para verificar as relações entre os dados de cor, temporada, e sexo. Os resultados confirmam claramente a hipótese relacionada à mudança sazonal de cor da pelagem, mas não confirmam diretamente a hipótese relacionada com alterações na cor da pelagem em relação ao sexo, e vamos mostrar a complexidade do modelo estudado. Em conclusão, sem dúvida, as variáveis estudadas devem consequentemente ser tidas em conta quando se estuda a coloração de amostras para caracterização, identificação e discriminação de diferentes unidades taxonômicas com base na cor.


Assuntos
Animais , Equipamentos de Medição de Riscos , Pigmentação da Pele , Sigmodontinae/anatomia & histologia , Variação Genética , Análise Espectral/métodos
16.
Córdoba; s.n; 2017. 92 p. tab.
Tese em Espanhol | LILACS | ID: biblio-983091

RESUMO

RESUMEN: Las Psicología aplicada al Deporte y en general las Ciencias de la Salud identifican al sedentarismo detectado en la población de jóvenes universitarios como un factor de riesgo para la salud. Por ello, se interesan en el diagrama de estrategias tendientes a lograr la adherencia a la práctica regular de las actividades físico deportivas. Este trabajo informa sobre el diseño y el análisis de las propiedades psicométricas de un cuestionario escalar para evaluar los valores que los jóvenes universitarios adjudican a la actividad físico- deportiva a partir de las propias vivencias que experimentan al realizarlas. Valores intrínsecos o contingentes a ella. La construcción de esta prueba intenta brindar una herramienta evaluativa que permita conocer las concepciones valorativas con las que el grupo a tratar califica el fenómeno a estudiar previo a la diagramación de estrategias de intervención. Los reactivos (ítems) que integran la escala, se diseñaron teniendo como guía orientadora los aportes teóricos de dos modelos Seirul.lo Vargas (1995) y Gómez Rijo (2001) que señalan la existencia de cuatro tipo de valores intrínsecos y los clasifican y definen como: Valor Agonístico, Valor Lúdico, Valor Hedonístico y Valor Higiénico...


Abstract: The Psychology applied to sport and general Health Sciences identified physical inactivity detected in the population of university students as a risk factor for health. Therefore, they interested in the diagram of strategies to achieve adherence to the regular practice of physical and sports activities. This paper reports on the design and analysis of the psychometric properties of a scale for the values that young university awarded physico sport activity from their own experiences that experience to perform questionnaire. Intrinsic values or contingent to it. The construction of this test is intended to provide an evaluation tool to provide a valuation concepts with which the group calls the phenomenon try to preintervention strategies diagramming study. Reagents (items ) that make up the scale were designed with as orientation guide the theoretical contributions of two models Seirul.lo Vargas (1995 ) and Gomez Rijo (2001 ) indicating the existence of four kinds of intrinsic values and classified and defined as : agonistic value , entertainment value , Hedonistic value and hygienic value. The conceptual scope of this scheme were modified from content analysis of open interviews with various members of the sports scene (athletes, technicians, professionals of applied sciences, etc.) that redefined locally. The study Content Validity of reagents was performed by the method of Judges (MAJ) which was attended by 11 experts professionals and 50 young men and women of similar characteristics to the target population...


Assuntos
Humanos , Adolescente , Exercício Físico/fisiologia , Atividades de Lazer , Equipamentos de Medição de Riscos , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Esportes
17.
Salud trab. (Maracay) ; 24(1): 27-37, jun. 2016. ilus, tab, graf
Artigo em Espanhol | LILACS, LIVECS | ID: biblio-846101

RESUMO

El objetivo de este estudio consistió en medir la intensidad de las vibraciones (en términos de aceleración) originados por máquinas en una empresa del sector agroindustrial, con la finalidad de ser comparados con los límites de exposición permisibles sugeridos en la norma ISO 2631-1 para establecer el riesgo al que están expuestos los colaboradores. El equipo utilizado fue un monitor de vibraciones VI- 400 Pro Quest Technologies, compuesto por un acelerómetro triaxial de pies - asiento o PCB 356B40. La investigación se efectuó en el pasillo donde están ubicadas dos centrífugas por medio de las cuales se recibe la masa cocida proveniente del tacho y se separa el cristal de la miel y en tres (3) grúas de hilo a través de las cuales se realiza el descargue de los trenes cañeros. Los hallazgos demostraron que existen diferencias en las vibraciones generadas por las grúas y en el pasillo donde están ubicadas las centrífugas, las intensidades de las vibraciones mostraron el siguiente comportamiento: 45,5% de las aceleraciones obtenidas por medio de mediciones en campo oscilan en un rango entre 8,0 m/s² y 1,15 m/s², representando un riesgo elevado para la salud de los trabajadores, el 54,5% de las mediciones superaron la intensidad de aceleración de 1,15 m/ s². Se recomienda realizar estudios posteriores que permitan la reducción del riesgo por exposición y el adecuado mantenimiento de las máquinas(AU)


The objective of this study was to measure the intensity of vibration (in terms of acceleration) caused by different machines in an agrobusiness company and compare them to the permissible exposure limits listed in the ISO 2631 Standard, and define any risks to which employees may be exposed. The equipment used was a 400 Pro Quest VI Technologies vibration monitor, which consists of a triaxial foot to seat accelerometer or PCB 356B40, which meets international standards ISO 2631-1, ISO 5349-2001, ANSI S3.34, ACGIH WBV 2004. The measurements were conducted in a hall where two centrifuges are located, through which the cooked mass sugarcane is run in order to separate honey from glass, and in three thread (3) cranes used to unload sugarcane trains. Results showed differences in vibration levels generated by the cranes and the halls where the centrifuges are located. Vibration intensity was as follows: 45.5% of the accelerations obtained through measurements varied from 8.0 m/s² to 1.15 m/s², representing a high health risk for workers; 54.5% of the measurements exceeded an acceleration intensity of 1.15 m/s². Recommendations include reduction of exposure levels and better machine maintenance(AU)


Assuntos
Padrões de Referência , Vibração , Normas Jurídicas , Maquinaria , Agroindústria , Riscos Ocupacionais , Saúde Ocupacional , Equipamentos de Medição de Riscos
18.
Rev. Soc. Odontol. La Plata ; 25(50): 21-26, jul. 2015. ilus, graf
Artigo em Espanhol | LILACS | ID: lil-768629

RESUMO

Siendo la estética una condición prioritaria en la cultura occidental y uno de los parámetros objetivos de la misma la simetría, este trabajo analiza la relación de las líneas medias interincisal del maxilar superior e inferior con la línea media facial. La población analizada fueron los alumnos de tercero, cuarto y quinto año, durante los años 2011 y 2012, de la Facultad de Odontología UCALP-SOLP, con criterios de inclusión y exclusión. Se seleccionó una muestra aleatoria de 66 alumnos de ambos sexos, con una edad promedio (SD) de 22.85 (2.86) años. La coincidencia del maxilar superior respecto a las coincidencias del maxilar inferior son significativamente mayores, Pr (T>t)=0.00, con un nivel de significatividad del 5 por ciento. Las diferencias en el maxilar superior son significativamente menores a las del maxilar inferior, P<0.05).


Assuntos
Humanos , Masculino , Feminino , Adulto Jovem , Assimetria Facial/diagnóstico , Assimetria Facial , Equipamentos Odontológicos , Equipamentos de Medição de Riscos , Argentina , Estudos Transversais , Epidemiologia Descritiva , Estética Dentária , Reabilitação Bucal/métodos , Interpretação Estatística de Dados
19.
Artigo em Inglês | LILACS | ID: lil-796382

RESUMO

To evaluate the use of electronic apex locator to measure the root canal length in primary teeth, comparing this measure with the measurements obtained by conventional radiography and by the direct measurement of the root canal lenght.Material and Methods:The sample consisted of nine multi-rooted primary teeth, totaling 32 root canals. Endodontic access was performed with a spherical diamond tip, then the pulp was extirpated and the canal irrigated with 0.9% saline. An endodontic file was used to measure the root canal length by electronic apex locator, using the Novapex ® according to the manufacturer's instructions, and by direct method. An endodontic ruler was used to determine fileÆs length. Conventional radiographic was also performed. Statistical analysis was performed by analysis of variance (ANOVA). The level of significance was 95%.Results:The average of the root canal length was 9.98 ± 2.16 to the direct method; 11.52 ± 1.87 to conventional radiography; and 10.91 ± 1.92 to the electronic apex locator. The results of this study showed a high correlation between the values given by the different methods, regardless of the presence or absence of physiological root resorption. There were not statistically significant differences amongst the methods studied (p> 0.05).Conclusion:Electronic apex locator was an accurate method measure the root canal length in primary teeth, and its use is indicated in endodontic treatment of these teeth...


Assuntos
Humanos , Cavidade Pulpar , Dente Decíduo/anatomia & histologia , Equipamentos de Medição de Riscos , Odontometria/métodos , Análise de Variância , Brasil , Radiografia Dentária
20.
Pulmäo RJ ; 24(1): 28-32, 2015. ilus
Artigo em Português | LILACS | ID: lil-764341

RESUMO

Em 2015 fazem exatamente cem anos desde a primeira publicação a descrever um método de aferição da respiração única de permeabilidade dos gases. Atualmente, os testes são realizados por sistemas automatizados utilizando a manobra de respiração única já padronizada internacionalmente. Este artigo aborda as técnicas usadas nesta medida, as equações de normalidade existentes e como interpretar dos dados obtidos. A interpretação dos resultados obtidos devem ser feita de forma cuidadosa. Tanto doenças obstrutivas como restritivas podem causar redução da capacidade de difusão ao monóxido de carbono. Quando usado em indicações clínicas bem estabelecidas e, principalmente, quando os resultados são analisados em conjunto com a clínica, radiologia e a medida dos volumes e fluxos pulmonares, o teste da difusão pode ser uma rica ferramenta no auxílio diagnóstico e prognóstico. Os aparelhos atualmente disponíveis no mercado para realização do teste são extremamente confiáveis, provendo exames reprodutíveis e acurados, no entanto, são equipamentos caros, devendo ser importados o que dificulta a disseminação da técnica.


In 2015 make exactly one hundred years since the first report describing a single-breath method of measuring permeability of gases. Currently, tests are performed by automated systems using the single breath maneuver already internationally standardized. This article discusses the techniques used in this measure, the existing normal equations and how to interpret the data obtained. The interpretation of the results obtained should be done carefully. Both obstructive and restrictive diseases can cause reduced diffusion capacity for carbon monoxide. When used in well-established clinical indications and especially when the results are analyzed together with the clinical, radiology and the measured lung volumes and flows, the diffusion test can be a rich tool in the diagnosis and can also provide the prognosis. Devices currently available in the market for the test are extremely reliable, providing reproducible and accurate tests. However, they are expensive equipment and must be imported which hinders the spread of technology.


Assuntos
Humanos , Masculino , Feminino , Capacidade de Difusão Pulmonar/métodos , Doença Pulmonar Obstrutiva Crônica/métodos , Técnicas e Procedimentos Diagnósticos , Equipamentos de Medição de Riscos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA